How much energy does a 1 MW tidal turbine generate over a tide? Vary the current speed to see how power output and rotor loads change. Year mode then gives an estimate of annual energy production. Choose English in the simulator’s language menu.

Open the simulator Understand the results

Try it for yourself

  1. Keep the initial settings and select Tide. Compare neap tides (coefficient 45) with spring tides (95). What happens to the peak of the power curve?
  2. Move the vertical cursor from slack water to peak current. Read the current speed, power and load at the same instant.
  3. Keep rated power fixed and lower the rated current speed. With automatic sizing enabled, see what rotor diameter is needed to reach the same power in a slower current.

Reading the results: three questions answered

What happens if current speed halves?

In this model, for the same turbine operating below its rated current speed, dividing current speed by two divides power by eight.

A turbine rated at 1 MW at 3 m/s delivers about 125 kW at 1.5 m/s.

See the equation

Why choose a larger rotor?

A larger rotor sweeps a larger area. With the same power coefficient, it can reach 1 MW in a slower current.

At the same current speed and thrust coefficient, doubling the diameter quadruples rotor thrust. A stronger support can cost more. Cavitation risk also depends on blade tip speed and submergence.

Try two rotor diameters

How much energy does 1 MW produce?

That depends on its output over time. At an average of 0.30 MW for 24 hours, it generates 7.2 MWh.

Estimate the capacity factor

Compare two rotor diameters

Keep rated power at 1 MW and the power coefficient at 0.40. Lower the rated current speed from 3.50 m/s (12.6 km/h or 6.8 kn) to 3.00 m/s (10.8 km/h or 5.8 kn). Compare the calculated diameter with the 15 m reference rotor.

← Back to the explanation of rotor diameter← Back to “What diameter is needed to reach 1 MW?”

1 m/s = 3.6 km/h ≈ 1.94 kn

← Back to the explanation of rotor diameter← Back to “What diameter is needed to reach 1 MW?”

The curves and energy estimates come from a simplified teaching model. A project-specific estimate requires site current data and the turbine’s power curve.

Explore the physics · Compare tidal streams across sites · Explore the HydreManche foundation

Technical background: equations and assumptions

Back to the simulator overviewOpen the simulator

Choose a question about the curve you are looking at.

For a fuller account with equations and examples, read the Technical Background.

From current speed to power

The power carried by water flowing through the rotor’s swept area is ½ ρ A V³. The model uses a seawater density ρ of 1,025 kg/m³. A is the swept area in m² and V is the current speed in m/s.

The power coefficient Cₚ is the fraction captured at the shaft. With Cₚ = 0.40, the rotor captures 40% before electrical losses. For a given turbine, doubling current speed multiplies captured power by eight on the cubic part of the curve. The model caps output at rated power.

See the illustrated equation on slide 4

Two diameters for the same rated power

To reach 1 MW in a slower current, a turbine with the same power coefficient needs a larger rotor. A larger swept area also means greater thrust at the same current speed and thrust coefficient.

This comparison varies the diameter of a horizontal-axis rotor. Both rotors use the same power coefficient. Blade pitch and blade profile are not modelled separately.

A larger rotor reaches the same power in a slower current. Consider two 1 MW turbines with Cₚ = 0.40. The reference rotor is 15 m in diameter and reaches 1 MW at about 3.02 m/s.

At 3.50 m/s, the required diameter is about 12 m. To try other values, compare two rotor diameters.

The diameter follows from the swept area needed to reach the stated power. For a disc, A = π D² / 4. Doubling the diameter quadruples the area.

Rotor thrust and loads on the support

Rotor thrust can be estimated as F ≈ ½ ρ Cₜ A V². With swept area and thrust coefficient Cₜ held constant, doubling the speed quadruples thrust. Thrust can keep increasing after power reaches its cap. The support also experiences drag, depending on its shape and exposed area.

Average power, energy and capacity factor

An average output of 0.30 MW over 24 hours gives 7.2 MWh. A 1 MW turbine running at rated power throughout could deliver 24 MWh. Dividing 7.2 by 24 gives a capacity factor of 30% for that day. A figure calculated over one tide or one day applies only to that period.

For a year of 8,760 hours, add the energy generated over successive tides. Applying the cubic law to the annual average speed would miss the effects of peak currents and the cap on power output.

Read the annual generation example on slide 5. Generating 2,000 MWh in a year from 1 MW of installed capacity corresponds to a capacity factor of about 23%.

From a tidal stream atlas to a site assessment

At a given location and tidal hour, you can interpolate between the current speeds shown for French tidal coefficients 45 and 95. Coefficient 70 is halfway between them, so use the average of the two speeds. Repeat for each tidal hour to see how speed varies over the cycle.

When the Alderney Race current weakens, what happens at Paimpol–Bréhat?

High water at Cherbourg (HW Cherbourg) is the common time reference. Select “Stream speed V”. In the Site column, select Alderney Race (Raz Blanchard) by name, choose “Keep only this site”, then tick Paimpol–Bréhat. The green and purple curves show each site relative to its own peak. Blue shows their equally weighted mean.

Place the cursor at a trough on the Alderney Race curve and read the speed at Paimpol–Bréhat in the table. The horizontal gap to the nearest trough on the Paimpol–Bréhat curve shows the phase difference. To estimate it in hours and minutes, move the cursor between the two troughs. On a phone, the cursor time appears just above the chart.

Closing the map tab will bring you back here to continue reading.

Compare the two sites on the interactive map (new tab)

To see how tidal height relates to current speed, read slides 11 to 13.

When the current remains strong at one site while weakening at another, the sites can complement each other’s output. To quantify this in MWh, you also need the installed turbines and their power curves. Site choice also depends on water depth, the seabed, grid connection, maintenance and other uses of the sea.

Interpreting Year mode and its limitations

The shorter modes use schematic current profiles. Year mode uses values representative of a strong-current area near Goury. The result is an order-of-magnitude estimate. A project assessment needs current data at rotor height and must account for wakes, turbulence, turbine availability and electrical losses.

Read HydreManche’s case for tidal energy in the English Channel

Browse the reference documents

Back to the simulator overviewOpen the simulator